| Parameter | Value |
|---|---|
| Current Type | AC |
| Installation | Duct Fan |
| Certifications | RoHS, ISO, CE, CCC |
| Speed Control | 0-10V DC/PWM |
| Rotation Direction | Clockwise (viewed from rotor side) |
| Protection Level | IP55 |
| Insulation Class | B |
| Packaging | Pallet |
| Dimensions | 485 x 485 x 104.5 mm |
| Operating Mode | S1 |
| Impeller Material | Plastic |
| Bearings | Ball Bearings |
| Housing Material | SPCC+S45C |
| Motor Protection | Self-resetting TOP wired internally |
| Airflow | 4000 m³/h (2354.31 CFM) |
| Number of Blades | 5 |
| Static Pressure | 105 Pa (0.421 inH₂O) |
| Lifespan | 50,000 Hours (L10) |
| Operating Voltage | 184-270 VAC |
| Operating Humidity | 5%-90% RH |
| Signal Output | FG (Frequency Generator) |
| Certifications | UL, CE, ROHS, CCC, ISO |
The High-Efficiency EC Axial Fan for Workshop is engineered to address the unique ventilation challenges of industrial environments, combining powerful airflow with exceptional energy efficiency. Driven by a permanent magnet EC motor, this fan consumes up to 75% less power than conventional AC axial fans while delivering a maximum airflow of 45.69 CFM . Its rugged construction meets IP54 protection standards, safeguarding internal components against dust, moisture, and industrial contaminants—critical for harsh workshop conditions . With an operating temperature range of -20°C to 60°C, it maintains performance stability even in extreme manufacturing environments .
The fan’s frame is constructed from UL 94 V-0 rated materials, providing fire resistance and mechanical strength to withstand vibrations and impacts common in workshops . The impeller features a variable pitch angle design, allowing fine-tuning of airflow patterns to target specific areas such as machinery stations or workbenches .
Integrated sensors monitor ambient conditions, enabling the fan’s microprocessor to adjust speed automatically—increasing airflow during peak production hours and reducing it during lulls . This dynamic modulation ensures optimal ventilation efficiency without manual intervention, cutting unnecessary energy use.
Equipped with premium ball bearings, the fan achieves an impressive 70,000 hours of operation at 40°C, translating to approximately 8 years of continuous use with minimal maintenance . The EC motor’s brushless design eliminates wear-prone components, significantly reducing downtime and replacement costs.
Perfect for metalworking, automotive, and electronics factories, where heat, fumes, and particulate matter require constant extraction. The fan’s high airflow rate effectively dilutes contaminants and regulates ambient temperatures.
In large storage facilities, the fan circulates air to prevent moisture buildup and maintain consistent conditions for inventory, particularly valuable for goods sensitive to temperature fluctuations.
Strategically positioned near assembly lines or welding stations, it directs focused airflow to cool workers and equipment, improving productivity and safety in heat-intensive operations.
The IP54 certification ensures protection against dust ingress and water splashes, while the fan’s self-cleaning impeller design minimizes debris accumulation during operation .
Yes, the fan supports daisy-chain connectivity through its control interface, allowing centralized management of multiple units via a single BMS or thermostat .
At maximum speed, the fan operates at 38-55 dB(A), comparable to conversational speech, ensuring it doesn’t contribute to excessive workplace noise pollution .

| Parameter | Value |
|---|---|
| Current Type | AC |
| Installation | Duct Fan |
| Certifications | RoHS, ISO, CE, CCC |
| Speed Control | 0-10V DC/PWM |
| Rotation Direction | Clockwise (viewed from rotor side) |
| Protection Level | IP55 |
| Insulation Class | B |
| Packaging | Pallet |
| Dimensions | 485 x 485 x 104.5 mm |
| Operating Mode | S1 |
| Impeller Material | Plastic |
| Bearings | Ball Bearings |
| Housing Material | SPCC+S45C |
| Motor Protection | Self-resetting TOP wired internally |
| Airflow | 4000 m³/h (2354.31 CFM) |
| Number of Blades | 5 |
| Static Pressure | 105 Pa (0.421 inH₂O) |
| Lifespan | 50,000 Hours (L10) |
| Operating Voltage | 184-270 VAC |
| Operating Humidity | 5%-90% RH |
| Signal Output | FG (Frequency Generator) |
| Certifications | UL, CE, ROHS, CCC, ISO |
The High-Efficiency EC Axial Fan for Workshop is engineered to address the unique ventilation challenges of industrial environments, combining powerful airflow with exceptional energy efficiency. Driven by a permanent magnet EC motor, this fan consumes up to 75% less power than conventional AC axial fans while delivering a maximum airflow of 45.69 CFM . Its rugged construction meets IP54 protection standards, safeguarding internal components against dust, moisture, and industrial contaminants—critical for harsh workshop conditions . With an operating temperature range of -20°C to 60°C, it maintains performance stability even in extreme manufacturing environments .
The fan’s frame is constructed from UL 94 V-0 rated materials, providing fire resistance and mechanical strength to withstand vibrations and impacts common in workshops . The impeller features a variable pitch angle design, allowing fine-tuning of airflow patterns to target specific areas such as machinery stations or workbenches .
Integrated sensors monitor ambient conditions, enabling the fan’s microprocessor to adjust speed automatically—increasing airflow during peak production hours and reducing it during lulls . This dynamic modulation ensures optimal ventilation efficiency without manual intervention, cutting unnecessary energy use.
Equipped with premium ball bearings, the fan achieves an impressive 70,000 hours of operation at 40°C, translating to approximately 8 years of continuous use with minimal maintenance . The EC motor’s brushless design eliminates wear-prone components, significantly reducing downtime and replacement costs.
Perfect for metalworking, automotive, and electronics factories, where heat, fumes, and particulate matter require constant extraction. The fan’s high airflow rate effectively dilutes contaminants and regulates ambient temperatures.
In large storage facilities, the fan circulates air to prevent moisture buildup and maintain consistent conditions for inventory, particularly valuable for goods sensitive to temperature fluctuations.
Strategically positioned near assembly lines or welding stations, it directs focused airflow to cool workers and equipment, improving productivity and safety in heat-intensive operations.
The IP54 certification ensures protection against dust ingress and water splashes, while the fan’s self-cleaning impeller design minimizes debris accumulation during operation .
Yes, the fan supports daisy-chain connectivity through its control interface, allowing centralized management of multiple units via a single BMS or thermostat .
At maximum speed, the fan operates at 38-55 dB(A), comparable to conversational speech, ensuring it doesn’t contribute to excessive workplace noise pollution .